IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The 0130F00038 is the genuine OEM auxiliary limit switch — identified by its light-blue housing color code — for the Goodman/Amana ACVM970803BNAA gas furnace. This secondary thermal safety mounts on the blower deck or burner box and opens the control circuit if it detects abnormal heat, providing backup protection beyond the primary high limit. The blue color indicates the factory trip-temperature rating; matching the correct color/setpoint is essential for proper protection.
The OEM 0130F00038 is pre-set to the exact trip point indicated by the blue color code. Substituting a different-color or universal limit risks an incorrect setpoint that either nuisance-trips or fails to protect the furnace. For a safety component priced this low, always replace with the matching genuine part.
Easy (1/5). Two spade terminals and a screw or clip mount — under 10 minutes. De-energize the furnace before servicing. Confirm the replacement is the same light-blue color rating before installing; do not mix limit colors.