The 10123529 is a genuine OEM manual-reset limit (rollout) switch for the Amana/Goodman AMVC800603BXAA gas furnace. This is a critical safety control: it opens the ignition/gas circuit if it senses abnormal heat from flame rollout or a blocked heat exchanger, and it must be manually reset once the fault is corrected. A tripped or failed switch will lock out the furnace and stop heat — replacing a bad switch (or one that will not reset) restores safe operation.
OEM guarantees the correct trip temperature and reset behavior your furnace is certified for. A generic switch with the wrong setpoint can either nuisance-trip or, worse, fail to protect against rollout. Because this is a safety device, always use the exact OEM part.
Rating: Easy-Moderate (3/5). Two spade terminals and one or two screws, power off. Simple mechanically — but a repeatedly tripping switch signals an underlying combustion or heat-exchanger problem that a licensed technician should diagnose before returning the unit to service.
Important: If this switch trips again after replacement, do not bypass it — have the furnace inspected. Confirm your model before ordering.