The Goodman B1370155 is a genuine OEM 120°F auxiliary limit switch for the Amana/Goodman AMS80905CNAA 80% AFUE gas furnace. Typically mounted in the blower compartment, this secondary safety opens the control circuit if temperatures climb too high due to restricted airflow — a dirty filter, blocked return, failed blower, or closed registers. It backs up the primary high limit to protect the heat exchanger from overheating.
This genuine OEM switch is set to the precise 120°F trip point and mounting footprint specified for this furnace. As a safety limit, the temperature calibration matters: a generic substitute with a different set point can cause repeated nuisance shutdowns or fail to protect the unit. Choose the OEM part for correct, code-compliant operation.
Easy (2/5). Turn off power, disconnect the two spade terminals, remove the mounting screws, and fit the replacement in the identical location and orientation. If the limit has been tripping, correct the airflow restriction (replace the filter, clear the return, verify blower operation) before restoring service. Cycle the furnace fully to confirm normal operation.
Compatible with Amana and Goodman furnaces. Verify your model and part number before ordering.