The Goodman B1370154 is a genuine OEM 350°F flame rollout switch for the GMPE125-5A gas furnace. This manual-reset safety limit is mounted at the burner assembly and shuts down the furnace if flames roll out of the combustion chamber — a critical protection against overheating and fire caused by a blocked heat exchanger or restricted flue. A tripped rollout switch always signals a condition that should be investigated.
As a safety-critical control, we recommend the OEM Goodman rollout switch. It is calibrated to the exact 350°F trip point and matches the original bracket and terminal layout. Generic substitutes may trip at the wrong temperature or fit poorly. Important: never bypass a rollout switch — if it keeps tripping, have a technician inspect the heat exchanger and venting.
Easy (1 of 3). Cut power, remove the mounting screws, transfer the spade terminals, and reinstall in the same location. About 10–15 minutes. Diagnose the root cause of any rollout trip before returning the furnace to service.