IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The B1370154 is a genuine Goodman OEM flame rollout switch rated to open at approximately 350°F, built for the GMN100-4 gas furnace. Mounted near the burner assembly, this manual-reset safety control shuts off the gas valve if flame rolls out of the burner box due to a blocked heat exchanger, cracked flue, or poor venting. It is a critical safety device — a tripped or failed rollout switch will keep the furnace from firing until the underlying condition is corrected and the switch is reset or replaced.
The OEM Goodman rollout switch is calibrated to the precise 350°F trip point and bracket geometry required for correct burner-box placement. A generic switch with a different set point can trip late — or not at all — compromising a life-safety function. Always use the OEM-spec part for rollout protection.
Easy — Single mounting screw or bracket clip with two spade terminals. A quick swap, but if the switch tripped, diagnose the cause (blocked exchanger/venting) before returning the furnace to service. Shut off gas and power first.