The Goodman B1370145 Flame Rollout Switch is a genuine OEM 300°F manual-reset safety limit for the AMH80904BXAA gas furnace. Mounted near the burner assembly, this switch senses excessive heat or flame rollout caused by a blocked heat exchanger or poor draft and shuts off the gas valve to prevent damage and hazards. If your furnace locks out on a rollout fault, this switch is a common and inexpensive replacement.
The OEM B1370145 is calibrated to the exact 300°F trip point and mounting footprint specified by Goodman. Because this is a life-safety component, an incorrectly rated generic switch can trip too early or fail to trip at all. The OEM switch guarantees correct protection and fit.
Easy — remove two screws and the spade connectors, then mount the new switch. Always diagnose and correct the root cause of a rollout before replacing. Shut off gas and power before servicing.