The OEM Goodman B1370145 rollout limit switch is a genuine 300°F manual-reset flame rollout safety used on AMH80903BNAB furnaces and other compatible Goodman and Amana models. It monitors the burner area and opens the gas/ignition circuit if flames roll out of the heat exchanger, shutting the furnace down to prevent damage or fire. A tripped or failed rollout switch will stop heating until it is reset or replaced.
The OEM B1370145 is calibrated to the exact 300°F trip point your furnace's safety sequence expects. Because this is a life-safety component, a generic switch with a different trip point or slower response can allow unsafe operation or cause nuisance lockouts. Always use genuine OEM for safety devices.
Easy. Cut power, unplug the two spade terminals, remove the mounting screws, and install the new switch in the same orientation. Always investigate why a rollout switch tripped (blocked flue, dirty burners, cracked heat exchanger) before returning the furnace to service.