IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370145 is a 300°F manual-reset flame rollout limit switch designed for the ADV80703BXBA gas furnace and other compatible Goodman/Amana models. Mounted on the burner assembly, this normally-closed safety switch opens and shuts off the gas valve if flame rolls out of the burner box — a critical protection against blocked heat exchangers, poor venting, or restricted combustion air.
The OEM B1370145 is calibrated to the exact 300°F trip point Goodman engineered for this burner design. Because this is a life-safety device that controls the gas supply, using the genuine part with the correct temperature rating is strongly recommended over generic substitutes that may trip early, trip late, or fail to reset properly.
Easy (2/5). Shut off power and gas, unplug the two spade terminals, remove the mounting screws, and install the new switch in the same orientation. Before returning the furnace to service, investigate why the original tripped — a rollout switch that opens almost always signals an underlying combustion or venting problem that must be corrected.