The Goodman B1370145 is a genuine OEM manual-reset flame rollout switch designed for the ADS80904BNA gas furnace and compatible Goodman/Amana models. Mounted on the burner box, it senses dangerous flame rollout conditions and shuts down the furnace to prevent overheating and unsafe operation. When it trips, it must be manually reset, alerting the homeowner that a service issue needs attention.
Our OEM B1370145 matches the factory trip point and bracket footprint exactly, ensuring proper safety response and a clean fit. Generic equivalents may carry looser temperature tolerances and slightly different mounting tabs, which can affect reliability of this critical safety component. For a part that protects against flame rollout, we recommend genuine OEM.
Easy — Two spade terminals and a single mounting screw. Always shut off gas and power before servicing. Typical replacement takes under 15 minutes for a qualified technician.