The Goodman B1370145 Flame Rollout Limit Switch is a genuine OEM safety component for GDT115-5 gas furnaces. This normally-closed manual-reset switch opens at 300°F to shut down the furnace if flames roll out of the burner box — protecting the heat exchanger, wiring, and cabinet from fire and heat damage. A tripped or failed rollout switch is a common cause of a furnace that lights briefly then shuts off.
Because this is a safety-critical component, we strongly recommend the OEM Goodman B1370145 — it carries the exact trip temperature and reset behavior your furnace was engineered for. Generic switches can have different trip points and should never be substituted on a life-safety device without verifying the rating.
Easy — Two spade terminals and a single mounting screw. Turn off power and gas, unplug the two wires, swap the switch, and reconnect. Never bypass or jump a rollout switch.