IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370145 is a genuine OEM 300°F flame rollout switch for the GMV80704BXA furnace and many compatible Goodman/Amana models. This manual-reset safety device monitors for flame rollout at the burner box and cuts power to the gas valve if it detects dangerous heat outside the heat exchanger. A tripped or failed rollout switch is a common cause of a furnace that ignites then shuts down or won't fire at all.
The OEM B1370145 is calibrated to Goodman's exact 300°F trip point and mounting footprint — critical for a life-safety component. Generic switches with approximate trip ratings can nuisance-trip or, worse, fail to protect. Always use OEM for safety controls.
Easy — Two spade terminals and a single mounting screw. Plan 10–15 minutes. Disconnect power and shut off gas before servicing; if the switch was tripped, diagnose the root cause (blocked flue, cracked heat exchanger) before restarting.