IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370145 Rollout Switch is a genuine OEM 300°F manual-reset flame rollout limit switch designed for the Goodman GMT070-4A gas furnace. This critical safety device mounts on the burner assembly and instantly cuts power to the gas valve if flames roll out of the burner box — a condition caused by a blocked flue, cracked heat exchanger, or restricted combustion air. When it trips, the furnace shuts down until the fault is corrected and the switch is manually reset.
The OEM Goodman switch is calibrated to the exact 300°F trip point specified for your furnace's burner geometry. Because this is a life-safety component protecting against carbon monoxide and fire, matching the factory trip temperature is essential — a generic switch with a different rating can nuisance-trip or, worse, fail to protect. Always replace with the OEM-specified part.
Easy. Turn off power and gas, unplug the two spade terminals, remove the mounting screws, and swap in the new switch. Most installs take under 15 minutes. Important: a tripped rollout switch signals a real combustion problem — diagnose and correct the root cause before returning the furnace to service.