The Goodman B1370145 Rollout Limit Switch is a genuine 300°F OEM safety control for the Goodman GMT070-3A gas furnace and compatible models. The flame rollout switch is a manual-reset thermal cutoff that shuts off the gas valve if flames roll out of the burner box — a key safety device that protects against a blocked heat exchanger or restricted flue. If your furnace locks out and the switch has tripped, it usually indicates an underlying combustion or venting problem that should be inspected.
This OEM switch is calibrated to the exact 300°F trip point and mounting/terminal spec your furnace requires. Because it is a life-safety component, using the factory-specified rating is essential — a mismatched generic trip temperature can either nuisance-trip or fail to protect. Always replace with the correct OEM rating.
Easy (1/5). Typically one or two screws and two spade terminals. Shut off power and gas, note wire positions, swap the switch, and restore power. About 10 minutes — but diagnose why it tripped before returning the furnace to service.