IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370145 is a genuine OEM 300°F manual-reset flame rollout limit switch for GMNT100-4B gas furnaces. Mounted on the burner box, it senses flames rolling out of the heat exchanger — a symptom of blockage or poor draft — and instantly shuts off the gas valve to prevent fire and heat-exchanger damage. A tripped or open rollout switch is a frequent no-heat cause.
The exact trip point and bracket footprint matter for a safety limit. The OEM B1370145 guarantees the correct 300°F set point and mounting; a mismatched generic can trip early (nuisance shutdowns) or, worse, too late. For safety controls we strongly recommend OEM.
Easy (2/5). Kill power, pull the two spade terminals, remove the mounting screws, and install the new switch in the same orientation. About 10 minutes. If the replacement trips again, diagnose the underlying draft or heat-exchanger fault — never bypass a rollout switch.
Genuine Goodman/Amana OEM safety part for the GMNT100-4B series.