The Goodman B1370145 is a genuine OEM manual-reset flame rollout limit switch rated to open at 300°F, designed for GDT045-3B gas furnaces. This safety control monitors the burner box for flame rollout and de-energizes the gas valve if flames escape the combustion chamber, protecting the furnace and home from overheating. A tripped or failed switch blocks ignition and is a critical safety component that must be replaced with an exactly rated part.
As a life-safety device, the trip temperature and reset behavior must match the furnace design exactly. Genuine Goodman B1370145 switches are calibrated to the correct 300°F set point. A mis-rated generic switch can defeat this protective function — OEM is required, not optional.
Easy (2/5). Usually two spade terminals and a single mounting screw or clip. Shut off power and gas, note the wiring, and swap. If the switch continues to trip, diagnose the underlying cause — blocked flue, dirty burners, or a cracked heat exchanger — before restoring service.
Fits Goodman GDT045-3B. Verify the printed 300°F rating before ordering.