IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370145 Rollout Limit Switch is a genuine OEM 300°F manual-reset safety control for GDS80703AXA gas furnaces and compatible Goodman/Amana models. Mounted on the burner assembly, this flame-rollout switch opens the ignition circuit and shuts the furnace down if flames roll out of the burner box — a critical safety response to a blocked heat exchanger, restricted flue, or failing inducer. A tripped or failed switch must be replaced with the exact temperature-rated OEM part to keep the furnace's safety chain intact.
This is a safety device — the OEM B1370145 is calibrated to the exact 300°F trip point specified for this furnace. A generic switch with the wrong temperature rating can trip too early (nuisance shutdowns) or too late (a genuine safety hazard). Always match the OEM rating on rollout switches.
Easy (2/5). Turn off power and gas, unplug the two spade terminals, remove the mounting screws, install the new switch in the same orientation, and reconnect. If the original tripped, diagnose and correct the root cause (blocked heat exchanger or flue) before returning the furnace to service. Use a licensed technician if unsure.