IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370145 is a genuine OEM flame rollout limit switch rated at 300°F, designed for the Goodman DDS80703AXA gas furnace and compatible models. Mounted near the burner assembly, this safety switch opens the ignition circuit if flames roll out of the heat exchanger — a critical protection against overheating, blocked venting, or a cracked exchanger. When it trips, the furnace locks out until the fault is corrected and the switch is reset.
The OEM Goodman B1370145 is calibrated to the exact 300°F factory trip point for reliable, code-compliant safety response. A generic 300°F rollout switch can be a lower-cost match — verify the trip temperature and terminal style precisely, since this is a safety-critical component.
Easy (2/5). Remove one or two mounting screws, transfer the two spade connectors, and reinstall — about 15 minutes. Always shut off power and gas first. Important: if a rollout switch trips repeatedly, have the heat exchanger and venting inspected by a licensed technician before returning the furnace to service.