IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370145 is a genuine OEM flame-rollout limit switch rated at 300°F for the AMV80704BXBA gas furnace. Mounted near the burner assembly, this manual-reset safety opens the gas valve circuit if flame rolls out of the burner box — a condition typically caused by a blocked heat exchanger or flue. It is a critical fire-safety device.
OEM B1370145 switches trip at the exact factory-specified 300°F setpoint. Generic substitutes with incorrect trip points can nuisance-trip or, worse, fail to protect against rollout. Because this is a life-safety component, install only the correct OEM-rated switch.
Easy — DIY friendly. Two screws and two spade terminals. Shut off gas and power first. If the switch has tripped, always diagnose and correct the root cause (blocked flue or cracked heat exchanger) before resetting or replacing.