IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370145 is a genuine OEM 300°F flame rollout switch for the AMV80703BXA furnace and compatible Goodman/Amana equipment. Mounted on the burner box, this manual-reset safety trips and cuts power to the gas valve if flames roll out of the burner compartment — protecting against a cracked heat exchanger, blocked flue, or restricted combustion air. A tripped or failed rollout switch will prevent the furnace from firing.
OEM vs. Generic: The OEM B1370145 is calibrated to the exact trip point and bracket geometry your furnace was engineered around. Generic rollout switches may differ in temperature rating or mounting footprint, risking either nuisance trips or, worse, a failure to trip during a genuine rollout event.
Install difficulty: Easy (1.5/5). Disconnect the two spade terminals, remove the mounting screws, install the replacement, and reconnect. Always shut off power and gas first, and diagnose the root cause before resetting or replacing a tripped rollout switch.