The Goodman B1370145 Flame Rollout Switch is the genuine OEM 300°F manual-reset safety limit for the AMS81155CXAA 80% AFUE gas furnace and compatible Goodman/Amana models. Mounted on the burner box, it senses flame rollout caused by a blocked heat exchanger or poor combustion airflow and shuts off the gas valve to prevent unsafe operation.
This is a factory-calibrated safety device. OEM B1370145 trips at the exact temperature and uses the correct terminal and bracket configuration your furnace expects. Substitute switches with the wrong set point or footprint can nuisance-trip or, worse, fail to protect. For a safety control, OEM is strongly recommended.
A tripped or failed rollout switch causes a no-heat, hard-lockout condition. Never simply jumper it — a trip indicates a real combustion or venting problem that must be corrected before installing the new switch.
Install difficulty: Easy to Moderate. About 15 minutes for a technician: remove two screws and the spade terminals, then mount the new switch. Because this is a combustion safety, professional diagnosis of the root cause is recommended.