IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370145 is a genuine OEM 300°F flame rollout limit switch for the Goodman/Amana AMS80905CNA gas furnace. This manual-reset safety device mounts near the burner box and cuts power to the gas valve if flame rolls out of the heat exchanger — a critical protection against a blocked flue, cracked exchanger, or restricted combustion air. A tripped or failed rollout switch will shut the furnace down and must be replaced with the exact temperature rating.
Rollout switches are life-safety components, and the trip point must match the furnace design exactly. The OEM B1370145 is calibrated to 300°F to Goodman's certification. A generic switch with a different set point can nuisance-trip or, worse, fail to trip when it should. We strongly recommend OEM for any combustion-safety part.
Rated Easy. Cut power and gas, note the two spade wire positions, unscrew the switch from the burner bracket, and mount the replacement in the same spot. Never bypass a rollout switch. If the switch tripped, find and correct the root cause (blockage, cracked heat exchanger) before returning the furnace to service.