IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The B1370145 is a genuine OEM flame rollout limit switch engineered for the Goodman/Amana AMS80903BNA gas furnace and many related 80% AFUE models. Mounted on the burner box, this manual-reset safety device instantly opens the gas valve circuit if flame rolls out of the burner compartment, protecting your heat exchanger and household from unsafe combustion conditions. When this switch trips, it is signaling a real problem — but a failed or aged switch that nuisance-trips should always be replaced with the correct OEM part.
Our OEM B1370145 is calibrated to the exact 300°F trip point Goodman engineered for this furnace, ensuring the safety circuit responds precisely as designed. Generic universal rollout switches may carry a similar rating but often use looser tolerances and non-matching bracket geometry, risking false trips or improper seating. For a life-safety component, we recommend OEM.
Easy (1/5). Power off the furnace, disconnect the two spade terminals, remove the mounting screws, and install the replacement. Typical job time is 10–15 minutes. Always confirm the root cause of any rollout before returning the unit to service.