The B1370145 flame rollout limit switch is a genuine Goodman/Amana OEM manual-reset safety device rated to open at 300°F, designed as a direct-fit replacement for the AMS80453AXAA gas furnace and compatible models. Mounted on the burner assembly, this switch detects flame rollout—a dangerous condition where flames escape the heat exchanger—and immediately shuts off the furnace to prevent fire and overheating. A tripped or failed rollout switch is a critical no-heat and safety fault that should never be bypassed.
The OEM B1370145 is calibrated to the exact 300°F trip point and terminal configuration your furnace's safety circuit expects. Substituting an incorrect temperature rating can allow unsafe operation or cause nuisance trips. Always use the OEM-rated switch for safety circuits.
Easy (2/5) — Power off the furnace, disconnect the two spade terminals, remove the mounting screws, and install the new switch. If the switch keeps tripping, do not bypass it—diagnose the root cause (blocked flue, cracked heat exchanger) with a licensed technician.