The Goodman B1370145 is a genuine OEM flame rollout limit switch rated to open at 300°F, used on the AMH80904BNAC gas furnace and compatible Goodman/Amana models. Mounted near the burner assembly, this manual-reset safety cutout trips if flame rolls out of the burner box due to a blocked heat exchanger or poor venting — shutting down the furnace to prevent damage and hazardous conditions. A tripped or failed rollout switch is a frequent cause of no-heat lockouts.
The OEM Goodman switch is calibrated to the exact 300°F set point the furnace safety circuit depends on. Because this is a safety-critical component, generic substitutes with different trip points or mounting are not recommended — a mismatched set point can nuisance-trip or, worse, fail to protect.
Easy (2/5). Disconnect power, remove two mounting screws, transfer the spade wire connectors, and reinstall. Always investigate why a rollout switch tripped before replacing it.