IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370145 Rollout Limit Switch is a genuine OEM 300°F manual-reset safety control for the AMH80704BNAC furnace and related Goodman/Amana 80% AFUE models. Mounted on the burner box, it trips to shut off the gas valve if flames roll out of the burner compartment — a critical safety device. A tripped or failed switch will stop the furnace from firing until it is reset or replaced.
Because this is a life-safety limit, the exact 300°F trip point and terminal layout matter. OEM guarantees the correct temperature rating and mounting. A mismatched generic switch can trip early (nuisance shutdowns) or too late (unsafe). Always use OEM for safety controls.
Easy — disconnect the two spade terminals, remove the mounting screws, and install the new switch. Plan 10–20 minutes with a nut driver. If a rollout switch keeps tripping, diagnose the underlying cause (blocked flue, cracked heat exchanger) before returning the furnace to service.