The Goodman B1370145 Flame Rollout Switch is a genuine OEM 300°F manual-reset safety limit for the Goodman/Amana ADV80905CXBB gas furnace. Mounted on the burner box, it trips and cuts power to the gas valve if flames roll out of the burner compartment — a critical safety response to a blocked heat exchanger, plugged flue, or failing inducer. A tripped or failed rollout switch will keep the furnace from firing until the fault is corrected and the switch is reset or replaced.
The OEM B1370145 is calibrated to Goodman's exact 300°F trip point and bracket footprint, ensuring the safety threshold matches the furnace's design. Our generic-compatible equivalent matches the same trip temperature and terminal layout at a lower price for out-of-warranty repairs. Both provide code-required rollout protection.
Easy (2 of 5). Turn off power and gas, remove the two mounting screws, transfer the two wires one at a time, and reinstall. Around 15 minutes. IMPORTANT: a rollout switch trips for a reason — always diagnose the underlying cause (heat exchanger, venting, inducer) before returning the furnace to service.