IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370145 is a genuine OEM flame rollout limit switch rated to open at 300°F. Mounted on the burner box, it is a critical safety control that shuts off the gas valve if flame rolls out of the heat exchanger — protecting against overheating and unsafe combustion. This switch is a direct-fit replacement for the Goodman/Amana ADV80703BXBB gas furnace. A tripped or failed rollout switch is a common no-heat cause; installing a fresh OEM control restores safe firing.
OEM rollout switches carry the exact 300°F calibration and mounting bracket required for reliable, code-compliant safety operation. Miscalibrated generics can nuisance-trip or, worse, fail to open at the correct temperature. On a safety device, use genuine OEM.
Easy — a 10–15 minute swap. Disconnect power, unclip the two spade terminals, unscrew the bracket, and mount the replacement. Note: if the original tripped, always diagnose the root cause (blocked flue, cracked exchanger) before restoring heat.