IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370145 rollout limit switch is the genuine OEM 300°F manual-reset safety control for ADS81155CXA gas furnaces. Mounted at the burner box, this switch trips and shuts off the gas valve if flame rolls out of the heat exchanger — a critical protection against a blocked exchanger or restricted venting. A tripped or failed rollout switch is a no-heat lockout that must be diagnosed and the root cause corrected before reset or replacement.
This is a life-safety device, so the calibrated 300°F trip point matters. The OEM Goodman switch is factory-set to the furnace's rollout spec. Generic switches may carry a different trip temperature or slower response, defeating the protection. Never substitute a different rating on a safety control.
Easy — two screws and two spade terminals. Shut off power and gas, transfer the wires, and mount in the original position. Important: a tripped rollout switch indicates a real combustion problem — inspect the heat exchanger and venting before returning the furnace to service.