IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370195 is a genuine OEM 300°F primary high-limit switch for the GDS80904BXA gas furnace. Installed on the heat exchanger or supply plenum, this control is the furnace's main overheat protection — it opens the gas valve circuit if supply air temperature climbs too high, usually due to insufficient airflow. A furnace that short-cycles on heat or won't stay lit often has a tripping or failed primary limit.
The OEM Goodman B1370195 is factory-calibrated to the exact 300°F set point and insertion depth your furnace requires. Because the primary limit directly controls the gas valve, an incorrectly rated generic switch risks nuisance lockouts or unsafe operation. OEM is the safe, correct choice.
Easy (2/5). Kill power to the furnace, disconnect the two terminals, remove the mounting screws, and slide the new switch into the same location. About 15 minutes with a nut driver. If the limit keeps tripping, check airflow and filter first.