The Goodman B1370108 Flame Rollout Switch is a genuine OEM manual-reset safety limit for the Goodman GUPS120-4 gas furnace. It guards against flame rollout — flames escaping the combustion chamber due to a blocked heat exchanger, cracked flue, or poor venting — by opening at 300°F to shut off the gas valve and stop the burners before overheating or fire can occur.
Because this is a life-safety control, the OEM Goodman switch is calibrated to the precise 300°F trip point required for the GUPS120-4. Generic equivalents with wider tolerances risk nuisance trips or delayed shutoff. On any safety device, fit OEM only.
Easy — disconnect the two spade terminals, remove the mounting screw(s), and install the replacement. About 15 minutes. Important: always identify and repair the underlying cause of a rollout trip (heat exchanger or venting) before restoring furnace operation.