IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370108 is a genuine OEM 300°F flame rollout switch (a manual-reset high-limit safety) for the Goodman GUPI120-5 gas furnace. Mounted near the burner box, it senses flame rollout — flames escaping the heat exchanger due to a blocked flue, cracked exchanger, or bad draft — and cuts power to the gas valve before the condition becomes dangerous. If your furnace locks out and won't restart, a tripped rollout switch is a common cause, but always find and fix the root problem before resetting.
Because this is a safety-rated component, we strongly recommend the OEM B1370108 — its trip point and reset behavior are validated to Goodman spec. A generic equivalent rated for 300°F may fit and function, but verify the temperature rating and terminal style exactly before installing on any safety circuit.
Easy (1/5). Disconnect power and gas, unclip the two spade terminals, remove two mounting screws, and swap in the new switch. Under 15 minutes with a nut driver. Never bypass or jumper a rollout switch.