IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370108 is a genuine OEM flame rollout safety switch designed as a direct-fit replacement for the Goodman GUPI100-4 gas furnace. Mounted on the burner assembly, this manual-reset thermal switch opens the control circuit and shuts off the gas valve if flames roll out of the burner box — a critical condition caused by a blocked flue, cracked heat exchanger, or restricted combustion air. It is a vital safety component that protects your home from fire and carbon monoxide hazards.
The OEM B1370108 is calibrated to the exact 300°F trip point and mounting footprint the GUPI100-4 burner box requires. A generic switch with a different set point can fail to trip during a genuine rollout event or nuisance-trip during normal firing. On a safety-critical component, only genuine Goodman calibration should be trusted.
Rating: Easy (1.5/5). Usually one or two screws and two spade terminals. Disconnect power at the breaker, note wire positions, and replace like-for-like. Important: if a rollout switch has tripped, have the underlying cause (blocked flue or cracked heat exchanger) diagnosed by a professional before returning the furnace to service.
Fast shipping and a 1-year warranty. Email info@nationalhvacparts.com with any questions.