The Goodman B1370108 Flame Rollout Switch is a direct-fit OEM safety limit for the Goodman GUN100-4B gas furnace and compatible Goodman/Amana/Janitrol models. This manual-reset switch trips at 300°F to shut down the gas valve if flames roll out of the burner box — protecting against blocked heat exchangers and improper venting.
The OEM B1370108 is set to the precise 300°F factory trip point, which is critical for a safety device. Our generic equivalent matches the temperature rating and terminal layout at a lower cost for out-of-warranty repairs. Both are warrantied. Never bypass a tripped rollout switch — always diagnose the root cause.
Easy. Disconnect power, pull the two spade terminals, remove the mounting screw, and install the new switch. A 10–15 minute repair.