IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370108 Flame Rollout Switch is the OEM burner-safety limit that shuts off the gas valve in the GUN100-4 furnace if flames roll out of the burner box. Rated to open at 300°F, it mounts on the burner assembly and detects the excess heat that occurs when a blocked heat exchanger or restricted flue forces combustion flame backward toward the cabinet — a serious fire and carbon-monoxide hazard.
A rollout switch is a life-safety device, and its trip point must be exact. The genuine Goodman B1370108 opens precisely at 300°F. Substituting a switch with a different rating defeats the safety design. Important: if this switch has tripped, find and correct the root cause (dirty burners, cracked heat exchanger, blocked flue) before resetting — never just replace and reset.
Easy (1.5 / 5). A single-screw mount and two spade terminals. Physically simple, but the underlying fault must be diagnosed by a qualified technician. Power and gas off before servicing.