IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370108 Flame Rollout Switch is a genuine OEM 300°F manual-reset limit switch for GDI150-5 furnaces. This critical safety device monitors the burner compartment for flame rollout — flames escaping the heat exchanger due to a blocked flue, cracked exchanger, or restricted venting. If temperatures spike, the switch opens and shuts off the gas valve to prevent fire and carbon-monoxide hazards. A tripped or failed rollout switch is a signal to inspect the venting and heat exchanger before returning the unit to service.
Because this is a life-safety component, we strongly recommend the OEM Goodman switch, which is calibrated to the exact 300°F trip point and bracket geometry. A Generic 300°F rollout switch can serve as a same-spec substitute, but verify the trip temperature and terminal style match before installing — never bypass or jumper a rollout switch.
Easy (2/5). Cut power and gas, disconnect the two spade terminals, remove the mounting screws, and install the new switch in the same orientation. Reset any related safeties and test for proper burner operation. If the switch had tripped, diagnose the root cause (venting, heat exchanger, airflow) before restarting.