The B1370108 is a genuine OEM Goodman 300°F flame rollout limit switch for GDI125-5 gas furnaces. Mounted on the burner assembly, this manual-reset safety switch shuts off the gas valve if flames roll out of the burner box — a critical protection against a cracked heat exchanger, blocked flue, or restricted combustion airflow. A tripped or failed rollout switch is a common reason a furnace locks out on ignition.
As a safety-critical component, the exact 300°F trip point is essential. This genuine Goodman OEM switch guarantees the correct rating and mounting fit. Avoid generic switches with mismatched temperatures — the wrong threshold defeats the protection this device provides.
Easy — 10 minutes. Cut power, unplug the two spade terminals, remove the mounting screws, and install the replacement in the same orientation.
Critical: a rollout switch trips for a reason. Always find and correct the root cause — heat exchanger crack, flue blockage, or combustion air restriction — before resetting or replacing it.