The Goodman CONT3P025024VS is a genuine OEM 3-pole definite purpose contactor built for the CPC036XXX3DXXXBA air conditioner and compatible Goodman/Amana condensing units. When the thermostat calls for cooling, the 24V coil pulls in the contacts to send line voltage to the compressor and condenser fan motor. Pitted or welded contacts, a chattering coil, or a contactor that won't pull in are classic causes of a no-cool condition — installing the correct OEM contactor restores clean, reliable switching and protects downstream components.
The OEM contactor matches Goodman's exact pole count, amp rating, coil voltage, and mounting footprint for a direct replacement. The Generic option is a UL-recognized 3-pole 25A / 24V equivalent at a lower price — confirm pole count and coil voltage before wiring. Both deliver dependable make-and-break performance under continuous HVAC duty.
Easy (1 of 3). Disconnect power at the breaker and confirm zero volts. Photograph the wiring, then move leads one at a time from the old contactor to the matching terminals on the new one. Re-mount and verify the 24V coil leads. Typical time is 20–30 minutes with a nut driver and multimeter. Never service a charged contactor.
Ships ready to install and backed by our fit guarantee for the listed model.