The Goodman CONT3P025024VS contactor is the OEM 3-pole, 25 amp switching relay with a 24-volt coil used on the GDT090-4 and compatible Goodman/Amana systems. The contactor energizes the compressor and condenser fan when the thermostat calls for cooling. Pitted or burned contacts, a chattering coil, or a stuck contactor are common causes of a unit that won't start or won't shut off.
Our OEM CONT3P025024VS matches the original amperage, pole count, coil voltage, and mounting footprint for a true drop-in fit. Generic contactors of a different amp rating or terminal layout can cause premature contact wear, wiring changes, or nuisance faults. For a reliable, code-correct repair, choose the OEM part.
Easy (2/5). About 15–20 minutes. Cut power at the disconnect and breaker, photograph the wiring, transfer leads one terminal at a time to the identical positions on the new contactor, and secure it to the bracket. Confirm the 24V coil pulls in on a cooling call.
Work with 120V/240V line voltage present — verify power is off before servicing. Confirm your model and serial before ordering.