IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370912S Primary Limit Switch is a genuine OEM high-limit safety control for the GMP125-5 gas furnace and compatible models. It features a 240°F trip point on a 7-inch insert probe that reaches into the heat exchanger air stream. If supply-air temperature climbs past the setpoint — usually from restricted airflow or blower failure — the switch opens to shut off the gas valve and prevent heat-exchanger damage, then automatically resets once the plenum cools.
This OEM limit is matched to the GMP125-5's exact trip temperature and probe length. A generic limit with the wrong setpoint or insert length can nuisance-trip on normal heating cycles or fail to protect the heat exchanger. For a safety limit, use the OEM part.
Easy (2/5). Disconnect power, remove the two mounting screws, unplug the spade terminals, and slide the new limit into the same opening with the probe fully inserted. If the old limit was tripping, correct the underlying airflow problem (dirty filter, failed blower, closed registers) before returning to service.