IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370192 is a genuine OEM primary high-limit switch built for the GMT140-5D gas furnace and compatible Goodman/Amana equipment. Positioned on the heat-exchanger bulkhead, this 230°F auto-reset control is the furnace's main overheat protector: it de-energizes the gas valve and burners if supply-air temperature climbs too high due to restricted airflow, a dirty filter, or a failing blower. A stuck-open primary limit is a frequent cause of no-heat and lockout faults.
The Goodman OEM primary limit is factory-calibrated to the precise 230°F cutout your furnace's design airflow demands. Universal high-limit switches with adjustable or approximate setpoints can allow dangerous overheating or cause frustrating short cycling. For the main safety control, we strongly recommend the exact OEM part.
Easy (1/5). Kill power, disconnect the two spade wires, remove the mounting screws, and fit the replacement in the same orientation. Expect 15 minutes or less. Always resolve airflow restrictions (filters, coils, blower) so the new limit isn't repeatedly tripped.