The Goodman 1370902S high-limit switch is a genuine OEM safety control for the GMNT100-4 gas furnace. This temperature-actuated switch is rated to open at approximately 210°F and mounts on a 3-inch insertion depth. It protects the furnace by cutting power to the gas valve if supply-air temperature rises too high — a condition usually caused by a dirty filter, blocked ductwork, or a failed blower. When a limit switch fails open or drifts, the furnace short-cycles on heat or refuses to fire.
The OEM switch is calibrated to the exact 210°F trip point and 3-inch stem length the GMNT100-4 heat exchanger requires. Substituting a generic limit with a different set point or insertion depth can allow overheating or cause false trips. For correct safety operation, use OEM.
Easy (2/5). Disconnect power, remove the two mounting screws and the spade wire connectors, and install the replacement in the same orientation. Roughly 15 minutes. Verify the disc sits flush against the mounting surface for accurate sensing.