OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The B1370190 is a genuine OEM primary limit switch designed for the Goodman/Amana ADV81155CXBB gas furnace and compatible upflow/horizontal models. This high-limit safety control monitors heat-exchanger and plenum temperature, opening the circuit to the gas valve and burners if the furnace overheats — typically caused by a dirty filter, blocked ductwork, or a failing blower motor. Replacing a nuisance-tripping or open limit restores safe, reliable heating.
Our OEM B1370190 is calibrated to Goodman's exact 210°F set point and disc geometry, ensuring proper mounting and correct cut-out/cut-in behavior. Aftermarket generic limits may vary in trip tolerance or bracket fit, risking short-cycling or premature failure. For a safety-critical control, OEM is the recommended choice.
Easy (DIY-friendly, ~15 minutes). Shut off power and gas, remove the two mounting screws, transfer the wire leads to the new switch, and reinstall. Basic hand tools only. Always confirm the airflow issue that caused the original trip before returning the furnace to service.