IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370189 is a genuine OEM primary high-limit switch rated at 200°F, built for the AMH80905CNAC and other compatible Goodman/Amana 80% AFUE furnaces. Positioned on the heat exchanger bulkhead in the supply-air stream, this auto-reset limit is the furnace's main overheat protection: if plenum temperatures climb too high due to restricted airflow, it opens to shut off the gas valve while keeping the blower running to purge residual heat. Once the cabinet cools, it resets automatically. A drifted or failed primary limit is a common cause of short-cycling and "limit open" lockouts.
Primary limits are matched to each furnace's heat-exchanger geometry and CFM design. The OEM B1370189 delivers the exact 200°F calibration and mounting flange, so the furnace protects and cycles as engineered. Aftermarket limits with a different setpoint risk nuisance trips or delayed shutdown.
Moderate. Requires removing two mounting screws on the heat-exchanger panel and transferring spade connectors; note orientation on removal. Estimated time: 20–30 minutes. De-energize power and gas before starting.