IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370198 Primary High-Limit Switch is the genuine OEM main temperature-limit control for the AMH81405DNAB gas furnace. Installed on the heat-exchanger bulkhead, it monitors supply-air temperature and shuts off the gas valve if the furnace overheats — the primary line of defense against heat-exchanger damage from restricted airflow.
The OEM Goodman B1370198 is calibrated to the exact 150°F opening temperature engineered for your furnace's heat rise. A mismatched generic limit can cause short-cycling or fail to protect the heat exchanger. For this safety-critical part, OEM is the right choice.
Easy (2/5). Shut off power and gas, remove the burner-compartment door, disconnect the two terminals, unscrew the limit from the bulkhead, and fit the replacement in the same orientation. Roughly 15–20 minutes. Check and replace a dirty filter to prevent repeat trips.