IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162903 is a genuine OEM primary high-limit switch with a 150°F trip point, built for the AMS81405DNBA gas furnace and compatible Goodman & Amana models. Mounted on the heat-exchanger partition, this control senses supply-air temperature and opens the burner/gas-valve circuit if the furnace overheats — typically caused by a dirty filter, blocked ductwork, or a failed blower. It is the furnace's front-line overheat protection and resets automatically once temperatures return to a safe range.
The OEM 20162903 is factory-matched to the 150°F set point and the exact insertion depth of the heat exchanger. Generic snap discs with the wrong trip temperature or probe length can allow the furnace to run too hot or trip prematurely, causing short-cycling and reduced heat-exchanger life. Genuine OEM ensures correct calibration and fit.
Easy (2/5). Kill power, disconnect the two spade terminals, remove the mounting screws, and install the replacement in the same orientation. No calibration required. If the limit keeps tripping, check airflow (filter, blower, ducts) before condemning the switch.