The Goodman 20162903 Primary Limit Switch is a genuine OEM high-limit safety control rated to open at 150°F, used in the WGFM195115S5DAC gas furnace. This normally-closed thermal switch monitors heat-exchanger temperature and shuts down the burners if airflow is restricted or the furnace overheats — a critical safety device protecting against cracked heat exchangers and fire hazards.
Limit switches are calibrated to a specific trip point and mounting footprint. This OEM Goodman switch trips at the exact 150°F the furnace's controls expect, ensuring proper safety response. Generic switches with slightly different set points can cause premature lockouts or, worse, fail to protect the heat exchanger. For a safety control, OEM is strongly recommended.
Easy (2/5). Cut power at the breaker, remove the two mounting screws, unplug the spade terminals, and install the replacement in the same orientation. No calibration needed. Confirm the trip temperature and bracket match your original before installing.