The Goodman 20162903 is a 150°F primary limit switch for the WGFM195090S5DAB gas furnace. Mounted on the heat exchanger/blower compartment, this bimetal-disc control monitors supply-air temperature and interrupts the burner circuit if the furnace overheats — typically caused by a dirty filter, blocked ducts, or a failing blower. It is auto-resetting, closing again once temperature returns to a safe range. Correct trip temperature is critical for both safety and comfort.
The OEM Goodman limit is factory-set to the exact 150°F trip point specified for this furnace. Generic switches with a different rating can cause short-cycling on heat or fail to protect the heat exchanger. For a safety limit, match the OEM temperature spec.
Easy (2/5). Power down, disconnect the terminals, remove two mounting screws, and install the replacement. Correct any underlying airflow restriction before returning the furnace to service.