The Goodman 20162903 is a primary high-limit switch with a 150°F trip point, designed for the WFM18090S4BXCC gas furnace and compatible Goodman/Amana models. Mounted on the heat exchanger or blower deck, this normally-closed control opens when supply-air temperature exceeds its rating and automatically closes once temperatures return to safe levels — protecting the furnace from overheating caused by restricted airflow, a dirty filter, or a failed blower.
The trip temperature and mounting depth are matched exactly on this genuine Goodman OEM switch. A generic limit with a different trip point or probe length can cause nuisance shutdowns or fail to protect the heat exchanger. For a temperature-critical safety device, OEM calibration matters.
Easy (2/5). Disconnect power at the breaker, pull the two spade terminals, remove the mounting screws, and install the replacement in the same orientation. About 10–15 minutes with a nut driver. If the limit continues to trip, check the air filter, blower operation, and ductwork for airflow restrictions.