IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The B1370198 is a genuine Goodman 150°F primary limit switch for the GMT070-3B gas furnace and compatible Goodman/Amana models. Mounted on the heat exchanger or blower deck, this primary high-limit control opens the gas valve circuit when supply air exceeds the safe threshold — typically caused by restricted airflow from a clogged filter, closed registers, or a weak blower. It is the furnace's front-line protection against heat exchanger overheating.
The OEM B1370198 is factory-set to 150°F with the correct probe length and mounting flange for the GMT070-3B cabinet. Generic limits with mismatched set points or probe depth can misread cabinet temperature and either short-cycle the furnace or allow unsafe overheating. OEM is the safe choice for a primary limit.
Easy (2/5) — Shut off power, note the wire routing, remove the two mounting screws, transfer the terminals, and reinstall. Roughly 15 minutes. Address the underlying airflow restriction before assuming the switch itself failed.