The Goodman 20162903 Primary Limit Switch (150°F) is a genuine OEM high-limit safety control for the GMH951155DXAG gas furnace. Mounted on the heat exchanger or burner bulkhead, this normally-closed thermal switch monitors supply-air temperature and cuts power to the gas valve if the furnace overheats — protecting against blocked airflow, a failed blower, or a dirty filter. A tripped or failed limit switch is a common cause of short-cycling and no-heat calls; replacing it with the correct 150°F trip-point part restores safe operation.
OEM (20162903): Calibrated to the exact 150°F trip point and mounting footprint this furnace requires — essential for a safety device. Recommended.
Generic: Aftermarket limit switches must match both the trip temperature and mounting bracket. Never substitute a different temperature rating.
Easy (2/5). Power down the furnace, unplug the two spade terminals, remove the mounting screws, and swap in the new switch. About 15 minutes with a nut driver. Confirm the trip rating stamped on the old part matches before installing.